Principle:
Placed the pulps, which is measured having a predetermined concentration, between the knife roller and the beating cylinder, rotating with different circumferential speeds. In order to achieve the purpose of beating pulp
Features:
Standard:
ISO 5264/2, TAPPIT248
Beating chamber | diameter 250mm, deep 52mm |
Knife rotor motor | Y90S-4,1.1Kw,380V/50HZ |
Knife Rotor | Dia. 200mm, height 50mm, blade thick 5mm |
Beating chamber Motor | YS-7124,0.37Kw,380V/50HZ |
Linear speed difference | (6.0 ± 0.2) m / s |
Beating pressure | (3.33 ± 0.1) N / mm Blade length |
(1.77 ± 0.1) N / mm Blade length | |
Beating gap adjustment distance | 0-25mm |
Photoelectric counter | Count 0-999999 |
Beating pulp concentration | 5-20% (recommend 10%) |
Dry pulp | 5-30g |
Dimensions | Host: 760×400×1000mm |
Electrical cabinet: 400×350×950mm | |
Weight | 350kg |